Relief ValveRelief valves play a crucial role in maintaining the safety and integrity of various systems by releasing excess pressure when it exceeds safe levels. Among the trusted names in the industry, Dixon Bayco stands out for its quality and reliability in manufacturing air pressure relief valves. In this blog post, we will delve into the theory of operation behind Dixon Bayco’s relief valves, exploring how they work and their essential features.

Dixon Bayco Relief Valves Operation

Dixon Bayco’s air relief valves are designed to function as spring-loaded, system-pressure actuated devices. They consist of a valve disc held in a closed position against a valve seat, thanks to the force exerted by a spring. Here’s how they operate:

Initial State: Valve Closed

At normal operating pressures, the spring load on the valve is sufficient to keep it closed. This ensures that the valve does not open under typical conditions.

Warning Pressure

When the system pressure begins to rise and approaches a level where it almost matches the spring load, the valve enters a state known as the warning pressure, cracking pressure, or hissing pressure. At this point, the valve may flutter on the seat, releasing a small amount of air without significantly relieving pressure.

Opening Pressure

As the system pressure continues to increase, it eventually surpasses the spring load. At this stage, the valve opens and remains open as long as the system pressure remains elevated. This point is called the opening pressure, set pressure, or popping pressure.

Full Opening

If the system pressure continues to rise, the valve continues to open further, allowing it to relieve more and more air. When fully open, the valve operates close to its maximum airflow rate. Further increases in system pressure at this stage result in only minor increases in flow rate.

Reseating Pressure and Blowdown

When the system pressure decreases, the valve begins to close. However, it won’t fully re-seat until the pressure drops below the opening pressure. This pressure difference is known as “blowdown,” and the point where reseating occurs is referred to as the reseating pressure.

To ensure safety, it’s crucial to match the valve to the system to be protected so that the maximum airflow rate of the valve is never exceeded. Overpressurization due to the valve relieving less air than is being added to the system can be dangerous.

Conclusion

In the world of pressure relief systems, Dixon Bayco stands as a trusted name, known for its quality and reliability. By understanding how their relief valves operate, we can better appreciate the critical role they play in maintaining safety and system integrity across a wide range of industries. It is through such advanced engineering and commitment to safety that Dixon Bayco continues to be a leader in the industry, providing peace of mind to countless organizations worldwide.

Got Questions? Let Us Help!

Kerley & Sears Inc. has been a family-owned and operated business since 1971. We specialize in the sales, service, and repair of pneumatic tools and industrial vacuum parts. With over 50 years in the industry, our customers can expect excellent customer service and can trust our expertise and quality work. We offer resale discounts and free estimates depending on the repair. Call us or stop by today!